Installation
SCS160 / SCS320 / SCS480 Page 22 www.thinklogical.com
SCS160R / SCS320R
3.1.2 Front Panel Display and Buttons
The front-panel LCD display should be visible and accessible during system setup.
It normally shows the current network settings and the date/time. The front panel but-
tons are only used during setup, or to review existing SCS settings.
The LCD display can be customized by the root user. See Section 7.7, Front Panel
Display Options, on page 57 for more information.
3.1.3 It’s Convection Cooled
The SCS does not require special cooling or ventilation other than what is normally
provided in an equipment rack. No fan means that it does not add to the ambient noise
in your equipment room. Be sure to not block the air vents on the sides of the unit,
and leave space on both sides. If mounted in an enclosed rack, it is recommended that
the rack have a ventilation fan to provide adequate airflow through the unit(s).
3.2 Connections
All connections are found on the rear of the SCS chassis. Each Port jack is clearly
labeled with the Port number.
Figure 3.1 SCS160 Chassis Rear View
3.2.1 Power
The SCS product has an internal universal AC power supply. Each SCS unit
requires approximately 15w of electrical power. The switching power supply accepts
nominal AC input voltage between 100-240 VAC with a frequency range of 50/60 Hz.
3.2.2 AC Input
A single IEC-type AC power entry module with an integral safety fuse and power
switch is found on the rear of the chassis for your AC power input. The power inlet to
the chassis uses a removable IEC-type cordset; one is provided with each system. Be
sure that your AC Power source is properly grounded.